Top

No spam, just the best from the world of Flos and design, we promise.

Filter by designers
All,
Filter by families
All,
Bellhop-Wall_deep_brown-1950X1950-17
Bellhop-wall-ceiling-Edward-Barber-Jay-Osgerby-Flos-Outdoor-C-thumb-01
Bellhop-wall-ceiling-Edward-Barber-Jay-Osgerby-Flos-Outdoor-C-thumb-02
Bellhop-wall-ceiling-Edward-Barber-Jay-Osgerby-Flos-Outdoor-C-thumb-03

Colors (7)

Bellhop Wall Dali

LED - 4000K - BEAM 85

Item Code: F003C41D018

Wall light version of the Bellhop Outdoor Collection for diffuse light, made of extruded and die-cast aluminium or stainless steel.
100-240V power supply integrated. Direct wall installation.
Each luminaire is equipped with 200 mm lenght cable for connection inside the luminaire body.
Reccomended connection wit a 2 way terminal block 4 poles IP68 H2O Stop, to be ordered separately.

Also available in: Bellhop Wall
Technical drawing
Schematic light drawing
Diffused light
  • Y
  • IP9
  • IK10
  • CM10
Main specifications
  • Lamp category: LED
  • Power (W): 8.00
  • CCT (K): 4000K
  • CRI: 80
  • Net lumen (lm): 607
  • Mountings: Wall
  • Environment: Outdoor
Optical
  • Lighting type: Direct
  • LED type: Power LED
  • Light distribution: Symmetric
  • Optical type: Diffused light
  • Beam angle (°): 85
  • Beam angle C90-270 (°): 85
Electrical
  • Frequency (Hz): 50-60
  • Voltage (V): 220-240
  • Dimmable: Yes
  • Driver: Integrated
  • Driver type: Electronic dimmable DALI
  • Emergency: Without
  • Insulation class: I
Physical
  • Color: Deep Brown
  • Orientation: Fixed
  • Weight (kg): 0.80
Notes

We recommend using a connection system with a degree of protection greater than or equal to the degree of protection of the luminaire. During the installation and the maintenance of the fixtures it is important to be careful and avoid damages on the paint coating. Damages on the coating exposed to outdoor conditions or water, could cause corrosion. Chemical substances affect the anticorrosion covering protection. For LED fixtures, there is evidence that most of the damages are connected to electrical effects related to the insulations, which cause destructive electrical discharges These effects are frequently caused by: • over voltage coming from the mains’ network where fixture is connected. • electrostatic discharge (ESD) coming from the environment. The use of a protective device against the overvoltage on the electrical installation is warmly suggest this helps to reduce the intensity of some of these phenomenon and prevent irreversible damages. The selection of the type of device to be used must be adjust on the electrical plant.

Choose the order code

Choose your language